登入 加入會員 求助
 
Shenzhen Heng Yi Jia Technology Co., Ltd.
 
 
Recommended Results 
 
Vacuum Plastic Chrome Coating Machine 

  產品分類 : 機械與設備->工業儀器設備->窯業設備

     
Vacuum Plastic Chrome Coating Machine
       

  產品規格
 
Model No:    HYJ-300
  Country  CN
  Brand  HENGYIJIA
  Packing  wood box
  Minimum Order  1
  Payment Term  T/T,Western Union

 

  產品描述
   
  Vacuum Plastic Chrome Coating Machine Working Principle:<br />
The Cathode combine with the Anode to form the arc discharge in vacuum environment, then release the ion from the Cathode.<br />
<p>
Due to the concentration of the current, It will produce the heat which will make the material plasma. The plasma react with the gas under the action of the sputter bombardment, to be coated at the surface of the products.
</p>
<p>
<table class="aliDataTable" style="margin:0px;padding:0px;font-size:12px;font-family:Arial, Helvetica, sans-senif;width:617px;color:#333333;background-color:#FFFFFF;">
<tbody>
<tr>
<td colspan="7" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Multi-Arc Ion Coating Equipment Model(Diameter less than 2m)</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Model</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">HYJ-1418</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">HYJ-1620</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">HYJ-1820</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">HYJ-2021</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">HYJ-2023</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">HYJ-2040</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Chamber</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">D1400×H1800mm</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">D1600×H2000mm</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">D1800×H2000mm</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">D2000×H2100mm</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">D2000×H2300mm</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">D2000×H4000mm</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Structure</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Vertical door, hanging or horizontal cart structure,&nbsp;pumping system and water cooling system</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Vacuum System</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Sustaining Pump + Mechanical Pump + Roots Pump + Diffusion Pump&nbsp;</span><br />
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">or Molecule Pump</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Measurement</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">1 set pirani, 1 set cold cathode, 1 set diaphragm gauge</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Power</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">DC power, MF power, pulse power(bias power, arc power)</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Ultimate Pressure</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">&nbsp;1.0 -&nbsp;6.0×10-4Pa, Non-loading cooling</span>
</td>
</tr>
<tr>
<td rowspan="2" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Arc Source</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">16-24 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">16-24 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">18-26 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">18-26 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">22-28 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">22-32 set</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">200A-300A</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">200A-300A</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">200A-300A</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">200A-300A</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">200A-300A</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">200A-300A</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Bias Power Supply</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">40KW/1 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">40KW/1 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">40KW/1 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">50KW/1 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">50KW/1 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">60KW/1 set</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Magnetron Power Supply</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">1-2 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">1-2 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">2-3 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">2-3 set</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">----</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">----</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Temp.</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Normal temperature - 450°C can be controlled and adjusted(PID temperature control)</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Gas</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Ar, N2, O2, C2H2,etc.</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Cooling</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Water cooling circulation, equip with industrial cooling tower or industrial water chiller(refrigerating machine)</span><br />
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">or cryogenic system.(customers provide)</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Controlling Method</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Manual, half-auto, auto, touch screen operation, PLC or computer controlled</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Supply Index</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Air Pressure 0.5-0.8MPa, Water Temp.≤25°C,Water Pressure≥0.2MPa</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Total Power</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">100~125KW</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">125~145KW</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">145~165KW</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">165~185KW</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">185~200KW</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">200KW</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Output Frequency</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Voltage 380V,Frequency 50HZ/60HZ</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Occupation Space</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">15~50m²</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">15~50m²</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">25~55m²</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">25~55m²</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">35~55m²</span>
</td>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">35~55m²</span>
</td>
</tr>
<tr>
<td align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Remark</span>
</td>
<td colspan="6" align="middle" valign="center" style="font-size:11pt;font-family:inherit;color:#000000;border:1px solid #CCCCCC;">
<span style="font-style:inherit;font-weight:inherit;font-size:12px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">customization</span>
</td>
</tr>
</tbody>
</table>
<img src="http://i.bosscdn.com/product/b2/3b/8b/f42bc3d8858a08eb3a937f5aaa.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=5&t=80&text=aGVuZ3lpdGVjaC5ib3NzZ29vLmNvbQ%3D%3D" width="700" height="525" title="Multi - arc ion plating machine" alt="Multi - arc ion plating machine" /><img src="http://i.bosscdn.com/product/8b/c9/8c/18e0d205c95e818c2c1b8229ee.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=5&t=80&text=aGVuZ3lpdGVjaC5ib3NzZ29vLmNvbQ%3D%3D" width="700" height="525" title="Multi-arc ion plating" alt="Multi-arc ion plating" /><img src="http://i.bosscdn.com/product/bc/fd/6c/13a7ffbe5d754595f267b0cfcb.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=5&t=80&text=aGVuZ3lpdGVjaC5ib3NzZ29vLmNvbQ%3D%3D" width="700" height="524" title="Vacuum multi - arc ion plating" alt="Vacuum multi - arc ion plating" />
</p>spraycoatingline.com

  其他類似產品
 
used pvd coating machine for sale

used pvd coating machine for sale
thin film deposition systems

thin film deposition systems
PVD Vacum Metalizing Machine

PVD Vacum Metalizing Machine
coating equipment for automotive lights

coating equipment for automotive lights
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .