登入 加入會員 求助
 
HebeiLongZhuoTradeCo.,LTD
 
 
Recommended Results 
 
Hanging Cross Flow Cooling Tower Film Fill 

  產品分類 : 機械與設備->工業儀器設備->切割設備

     
Hanging Cross Flow Cooling Tower Film Fill
       

  產品規格
 
Model No:    CF915-MA
  Country  CN
  Brand  Long Zhuo
  Packing  Wooden Pallet, Wooden Crate or as your requirement
  Minimum Order  100
  Payment Term  L/C,T/T,Paypal,Western Union

 

  產品描述
   
  <h1 style="text-align:center;font-weight:400;font-size:19px;font-family:Helvetica, Tahoma, Arial, sans-serif;vertical-align:baseline;color:#333333;">
<span style="font-style:inherit;font-weight:inherit;line-height:24px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;"><span style="font-family:Arial;color:#000000;"><strong><span>Hanging Cross Flow Cooling Tower Film Fill</span></strong></span></span>
</h1>
<h1 style="font-weight:400;font-size:19px;font-family:Helvetica, Tahoma, Arial, sans-serif;vertical-align:baseline;color:#333333;">
<span style="font-style:inherit;font-weight:inherit;line-height:24px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;"><span style="font-family:Arial;font-size:16px;color:#000000;">
<p style="font-family:arial, serif;vertical-align:baseline;color:#444444;">
<span style="font-style:inherit;font-weight:inherit;font-size:16px;line-height:24px;font-family:inherit;vertical-align:baseline;color:#000000;background-color:#FFFFFF;"><span style="font-style:inherit;font-weight:inherit;font-size:inherit;line-height:21px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">Hanging Cross Flow Cooling Tower Film Fill is available in configuration and higher-performing configuration. It is a hanging film type cooling tower fill which spreads the water into a thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow. This type of fill provides much more water surface exposure per cubic foot than splash type fill.</span><span style="font-style:inherit;font-weight:inherit;font-size:inherit;line-height:24px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;">&nbsp;</span></span>
</p>
<p style="font-family:arial, serif;vertical-align:baseline;color:#444444;">
<span style="font-style:inherit;font-weight:inherit;font-size:16px;line-height:21px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;background-color:#FFFFFF;color:#000000;">This MX75 cooling tower fill incorporates highly efficient cellular drift eliminators, integrally molded within the fill sheets. Compared with previous designs, these eliminators reduce drift emissions from the tower by a factor of ten or more! Less drift means tower owners save water bills and water treatment chemical expenses.</span>
</p>
<p style="font-family:arial, serif;vertical-align:baseline;color:#444444;">
<span style="font-style:inherit;font-weight:inherit;font-size:16px;line-height:21px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;background-color:#FFFFFF;color:#000000;">This fill virtually eliminates the nuisance caused by drift spotting on adjacent buildings and property. For additional savings, the drift eliminators discharge air directly toward the fan. Discharge air, traveling in the right direction when it leaves the eliminators, translates to lower fan horsepower.</span>
</p>
<p style="font-family:arial, serif;vertical-align:baseline;color:#444444;">
<span style="font-style:inherit;font-weight:inherit;font-size:16px;line-height:21px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;background-color:#FFFFFF;color:#000000;">Louvers are also integrally molded within the fill sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow. Unlike towers equipped with separate external louvers, this fill operates virtually ice-free even in extremely cold weather.</span>
</p>
<p style="font-family:arial, serif;vertical-align:baseline;color:#444444;">
<span style="font-style:inherit;font-weight:inherit;font-size:16px;line-height:21px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;background-color:#FFFFFF;color:#000000;">MX fill is thermoformed from PVC with a flame spread rating less than 25 per ASTM E-84 and is considered selfextinguishing. Therefore, the risk of fire damage is minimal.</span>
</p>
<p style="font-family:Arial, Helvetica;vertical-align:baseline;color:#333333;">
<span style="font-style:inherit;font-weight:inherit;font-size:16px;line-height:18px;font-family:arial, helvetica, sans-serif;vertical-align:baseline;background-color:#FFFFFF;color:#000000;"><em><span style="font-style:inherit;font-weight:inherit;font-size:inherit;line-height:21px;font-family:inherit;vertical-align:baseline;">We&nbsp;have&nbsp;many&nbsp;years&nbsp;for&nbsp;exported&nbsp;Cooling&nbsp;towers&nbsp;filling,&nbsp;we&nbsp;are&nbsp;professional&nbsp;for&nbsp;in</span><span style="font-style:inherit;font-weight:inherit;font-size:inherit;line-height:21px;font-family:inherit;vertical-align:baseline;">s</span><span style="font-style:inherit;font-weight:inherit;font-size:inherit;line-height:21px;font-family:inherit;vertical-align:baseline;">tallation&nbsp;and&nbsp;production&nbsp;</span></em></span>
</p>
<img src="http://i.bosscdn.com/product/65/ea/68/40a0a808292c46a9f3e837c7d1.jpg" title="MX75 Cooling Tower Fill " alt="MX75 Cooling Tower Fill " /></span></span>
</h1>
<h1 style="font-weight:400;font-size:19px;font-family:Helvetica, Tahoma, Arial, sans-serif;vertical-align:baseline;color:#333333;">
<span style="font-style:inherit;font-weight:inherit;line-height:24px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><span style="font-style:inherit;font-weight:inherit;line-height:21px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"></span></span>
</h1>
<p>
<span style="font-style:inherit;font-weight:inherit;line-height:24px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><span style="font-style:inherit;font-weight:inherit;line-height:21px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><br />
</span></span>
</p>
<p>
<span style="font-style:inherit;font-weight:inherit;line-height:24px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><span style="font-style:inherit;font-weight:inherit;line-height:21px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><strong><strong>Cooling Tower Fill Material:</strong><br />
</strong></span></span>
</p>
<p>
<span style="font-style:inherit;line-height:24px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><span style="font-style:inherit;line-height:21px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;">Cooling tower fill material can be PVC or PP.</span></span>
</p>
<p>
<span style="font-style:inherit;font-weight:inherit;line-height:24px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><span style="font-style:inherit;font-weight:inherit;line-height:21px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><strong><img src="http://i.bosscdn.com/product/8a/17/a6/7b28ebad2db311ddead767747d.jpg" title="MX75 Cooling Tower Fill " alt="MX75 Cooling Tower Fill " /><br />
</strong></span></span>
</p>
<p>
<br />
</p>
<p>
<span style="font-style:inherit;font-weight:inherit;line-height:24px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><span style="font-style:inherit;font-weight:inherit;line-height:21px;font-family:Arial;vertical-align:baseline;font-size:16px;color:#000000;"><strong>Cooling Tower Fill Production Line:</strong></span></span>
</p>
<p style="font-family:Arial, Helvetica;">
<img src="http://i.bosscdn.com/product/27/2e/15/afc5a26a3442e150d3f663a5a9.jpg" title="MX75 Cooling Tower Film fill" alt="MX75 Cooling Tower Film fill" />
</p>
<p style="font-family:Arial, Helvetica;">
<span style="font-family:sans serif , tahoma, verdana, helvetica;"><strong><span style="font-size:16px;font-family:Arial;"><br />
</span></strong></span>
</p>
<p style="font-family:Arial, Helvetica;">
<span style="font-family:sans serif , tahoma, verdana, helvetica;"><strong><span style="font-size:16px;font-family:Arial;">Co</span></strong></span><strong><span style="font-size:16px;font-family:Arial;">oling Tower Fill Packing and Shipping:</span></strong>
</p>
<span><span style="color:#000000;"></span>
<p style="font-family:Arial, Helvetica;">
<span style="font-size:16px;color:#000000;"><strong></strong></span><span style="font-size:16px;color:#000000;"><strong></strong></span>
</p>
<p style="font-family:Arial, Helvetica;">
<span style="font-size:16px;color:#000000;"></span>
</p>
</span>
<p>
<span style="font-style:inherit;font-weight:inherit;line-height:24px;vertical-align:baseline;font-size:16px;font-family:Arial;"><span style="font-style:inherit;font-weight:inherit;line-height:21px;vertical-align:baseline;font-size:16px;font-family:Arial;"><span style="font-size:16px;font-family:Arial;"><span style="color:#000000;font-size:16px;font-family:Arial;">It can be packed into wooden pallet, wooden crate or just PE belt load in container.</span></span></span></span>
</p>
<p>
<span style="font-style:inherit;font-weight:inherit;line-height:24px;vertical-align:baseline;font-size:16px;font-family:Arial;"><span style="font-style:inherit;font-weight:inherit;line-height:21px;vertical-align:baseline;font-size:16px;font-family:Arial;"><span style="font-size:16px;font-family:Arial;"><span style="color:#000000;font-size:16px;font-family:Arial;"><img src="http://i.bosscdn.com/product/dd/99/f0/c3cee4952f215bc796591a44e1.jpg" title="Cooling Tower Fill " alt="Cooling Tower Fill " /><br />
</span></span></span></span>
</p>
<p>
<strong><span style="font-size:16px;font-family:Arial;">Contact Information:</span></strong>
</p>
<p>
<strong><span style="font-size:16px;font-family:Arial;"><img src="http://i.bosscdn.com/product/f6/69/67/8bddc39014c00482ad362f26d0.jpg" title="Cooling Tower Fill contact" alt="Cooling Tower Fill contact" /><br />
</span></strong>
</p>hblongzhuo.com

  其他類似產品
 
Honeycomb Counter Flow Cooling Tower Fill Block

Honeycomb Counter Flow Cooling Tower Fill Block
1300mm Cooling Tower Fill Filter Media

1300mm Cooling Tower Fill Filter Media
Long Distance 9999m Distance Measuring Wheel

Long Distance 9999m Distance Measuring Wheel
19mm PVC Cooling Tower Fill Pack

19mm PVC Cooling Tower Fill Pack
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .