登入 加入會員 求助
 
Jiangsu Tianyuan Testing Equipment Co., LTD
 
 
Recommended Results 
 
Lzod/Charpy Impact Testing Machine 

  產品分類 : 食品飲料->其他->烘焙機

     
Lzod/Charpy Impact Testing Machine
       

  產品規格
 
Model No:    TY-4020
  Country  CN
  Brand  TIANYUAN
  Packing  wooden package
  Minimum Order  1
  Payment Term  L/C,T/T

 

  產品描述
   
  Equipment name: TY-4020A/TY-4021A&nbsp;Pendulum impact testing machine<br />
<br />
Equipment usage:<br />
mainly used to make plastics and hard rubber, glass fiber, glass fiber, glass reinforced plastics, electrical insulation materials, floor tile of pottery and porcelain, cast stone, friction material of simply supported beam and cantilever beam impact test.<br />
<br />
Applicable standard:<br />
GB/T 1043-1043 "hard plastic beam impact test method"<br />
GB/T 1843-1843 "plastic cantilever beam impact test method"<br />
JB/T8761-1998 "plastic cantilever beam impact test"<br />
JB/T 8762-8762 "plastic beam impact testing machine"<br />
ISO 179:1993&nbsp; Plastics &nbsp;-Determination &nbsp;of &nbsp;Charpy&nbsp;&nbsp;impact &nbsp;properties<br />
ISO 180: 2000 Plastics &nbsp;-Determination &nbsp;of &nbsp;Lzod &nbsp;impact &nbsp;strength<br />
GB/T 18743-18743 "fluid with thermoplastic pipe transmission beam impact test method" (that is applicable to pipe impact)<br />
<br />
Feature:<br />
1. Choose imported high precision ball bearing, effective pendulum energy losses to a minimum<br />
2. With high precision photoelectric encoder, to avoid the pointer of the friction energy loss, caused by the equipment operation is simple, easy to use<br />
3. Using carbon fiber shock, reduce the error brought by itself quality factors<br />
4. Can configure multiple pendulum and corresponding support, and easy to change<br />
5. Can increase safety nets, improve the security performance of the tester<br />
6. Equipped with a special liquid crystal display can display the impact absorbing energy and intuitive accurate without having to read data from the dial, without reading error, high accuracy, high efficiency<br />
7. The built-in energy loss can be corrected&nbsp;,&nbsp;making&nbsp;the test results more accurate<br />
8. The printer can print out the test report<br />
9. Customised version can do software even use a computer<br />
<br />
<p>
Technical parameter:
</p>
<p>
<table class="MsoTableGrid" style="border:medium none;" cellspacing="0" cellpadding="0" border="1" align="left">
<tbody>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Model
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="281" valign="top">
<p class="MsoNormal">
TY-4020A
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal">
TY-4021A
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Name
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="139" valign="top">
<p class="MsoNormal">
Simply supported beam
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal">
Simply supported beam
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal">
Cantilever beam
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Impact energy
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="139" valign="top">
<p class="MsoNormal" align="center">
1J.2J.4J.5J
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="center">
7.5J.15J.25J.50J
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="95" valign="top">
<p class="MsoNormal" align="center">
1J.2.75J.5.5J
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="66" valign="top">
<p class="MsoNormal" align="center">
11J.22J
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Pendulum angle
</p>
</td>
<td colspan="4" style="border:solid windowtext 1.0pt;" width="442" valign="top">
<p class="MsoNormal">
150°
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Impact speed
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="139" valign="top">
<p class="MsoNormal" align="center">
2.9m/s
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="center">
3.8m/s
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal">
3.5m/s
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Distance between center of pendulum
and sample
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="139" valign="top">
<p class="MsoNormal" align="center">
221mm
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="center">
380mm
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal" align="left">
Distance between pendulum center
and impact blade:335mm
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Distance between impact blade and
jaw
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="281" valign="top">
<p class="MsoNormal" align="center">
40mm.60mm.70mm.95mm
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal" align="left">
Distance between impact blade and
jaw: 22mm
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Impact blade angle
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="281" valign="top">
<p class="MsoNormal" align="center">
30°
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal" align="center">
Blade radius: R=0.8mm
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Impact blade radius
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="281" valign="top">
<p class="MsoNormal" align="center">
R=2mm
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal" align="center">
&nbsp;
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Size(L*H*W)
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="281" valign="top">
<p class="MsoNormal" align="center">
700×800×300mm
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal" align="center">
&nbsp;700×800×300mm
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Weight
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="139" valign="top">
<p class="MsoNormal" align="center">
90Kg
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="center">
150Kg
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="95" valign="top">
<p class="MsoNormal" align="center">
90Kg
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="66" valign="top">
<p class="MsoNormal" align="center">
110 Kg
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="142" valign="top">
<p class="MsoNormal" align="left">
Power supply
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="281" valign="top">
<p class="MsoNormal" align="center">
220V&nbsp; 200W
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="161" valign="top">
<p class="MsoNormal" align="center">
220V&nbsp; 200W
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/6c/02/d2/4fea118ee90f22d3a58a5557ad.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=21&p=5&t=80&text=dGVuc2lsZXRlc3QuYm9zc2dvby5jb20%3D" title="Lzod Impact Testing Machine" alt="Lzod Impact Testing Machine" />
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/87/3c/84/73ae93e291b489a8431730b272.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=21&p=5&t=80&text=dGVuc2lsZXRlc3QuYm9zc2dvby5jb20%3D" title="Charpy Impact Testing Machine" alt="Charpy Impact Testing Machine" />
</p>
<p>
<br />
</p>tytesting.com

  其他類似產品
 
Rubber Fatigue Crack Test Equipment

Rubber Fatigue Crack Test Equipment
Melt Flow Rate Instrument

Melt Flow Rate Instrument
Fabric Oxygen Index Tester

Fabric Oxygen Index Tester
Metal Material Salt Spray Tester

Metal Material Salt Spray Tester
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .