XLPE Insulation and High Voltage Type 132kV power cable 

  產品分類 : 電子電工->電子零件->撓性扁平電纜

     
XLPE Insulation and High Voltage Type 132kV power cable
       

  產品規格
 
Model No:    YJV
  Country  CN
  Brand  HUAYUAN YONGTONG
  Packing  DRUMS
  Minimum Order  1000
  Payment Term  L/C,T/T,D/P,Western Union

 

  產品描述
   
  <p>
<span style="font-size:16px;font-family:'Times New Roman';">XLPE Insulation Material and High Voltage Type 132kV power cable</span>
</p>
<p>
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">A high-voltage cable (HV cable) is a cable used for electric power transmission at high voltage. A cable includes a conductor and insulation, and is suitable for being run underground or underwater. This is in contrast to a conductor, which does not have insulation. High-voltage cables of differing types have a variety of applications in instruments, ignition systems, and AC and DC power transmission. In all applications, the insulation of the cable must not deteriorate due to the high-voltage stress, ozone produced by electric discharges in air, or tracking. The cable system must prevent contact of the high-voltage conductor with other objects or persons, and must contain and control leakage current. Cable joints and terminals must be designed to control the high-voltage stress to prevent breakdown of the insulation. Often a high-voltage cable will have a metallic shield layer over the insulation, connected to the ground and designed to equalize the dielectric stress on the insulation layer.</span>
</p>
<p>
<span style="font-size:16px;font-family:'Times New Roman';"></span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">Standand</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">1) IEC 60060:2010 High Voltage Testing Technology;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">2) IEC 60228:2004 Insulated Cable Conductor;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">3) IEC 60229:2007 Test on Extruded Cable Sheath with Special Protective Function;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">4) IEC 60230:1966 Impact Test on Cable and Cable Accessories;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">5) IEC 60071:2006 Insulation Co-ordination;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">6) IEC 60287:2006 Rated Continuous Current Calculation of Cable;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">7) IEC 60811:2001 Non-electrical Test &amp; Material Test;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">8) IEC 60859:1999 Jointing of Cable and GIS with Rated Voltage of 72.5kV and Above;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">9) IEC 60949:2008 calculation of permissible short circuit thermal stability current considering the effect of non- &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;insulated heat;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">10) IEC 60885:1988 Electrical Test Methods for Power Cable;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">11) IEC 60183:1990 High Voltage Cable Select Guide;</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;IEC 62067:2006 Extruded Insulated Power Cable</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">12) Test Method and Requirement with Rated Voltage of 150kV(Um=170kV) to 500kV (Um=550kV);</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">13) IEC60840:2004 Extruded Insulated Power Cable</span>
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Test Method and Requirement with Rated Voltage of 30kV(Um=36kV) to 150kV (Um=170kV).</span>
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
<span style="font-size:16px;font-family:'Times New Roman';">Meanwhile, our company can also manufacture cable products according to other standards such as ASTM, AS and BS Standard.</span>
</p>
<p class="MsoNormal">
<span style="font-weight:700;color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">Remark,</span><br />
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">1. System Frequency is 50Hz;</span><br />
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">2. During Normal Operation, Allowable Maxi Cable Conductor Temperature is 90℃;</span><br />
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">3. During short circuit (short circuit duration no more than 5S), Max. Cable Conductor Temperature is&nbsp;250℃;</span><br />
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">4. Cable Service Life is at least 30 Years;</span><br />
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">5. No drop restrictions during Cable laying. The ambient temperature should be Min 0℃, or it should be&nbsp;heated before laying;</span><br />
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">6. Allowable Max. Pulling force for conductor Cu cable:70N/mm2 Al cable: 40N/mm2;</span><br />
<span style="color:#333333;font-family:'Times New Roman';font-size:16px;line-height:21px;background-color:#FFFFFF;">7. Allowable side pressure Max. 5kN/m;</span>
</p>
<p style="font-family:Arial, Helvetica, sans-senif;font-size:14px;vertical-align:baseline;color:#333333;background-color:#FFFFFF;">
<span style="font-size:16px;font-family:'Times New Roman';">8. The minimum bend radius is 20D during cable laying, and 15D during operation.</span>
</p>
<p>
<br />
</p>
<p class="p" style="margin-left:-3.0000pt;vertical-align:baseline;">
<br />
</p>
<br />
<img src="http://i.bosscdn.com/product/db/23/82/fa3bc86391330beea82dbaae56.jpg" title="XLPE-Insulated-Armoured-PVC-Sheathed-Power-Cable (1)" alt="XLPE-Insulated-Armoured-PVC-Sheathed-Power-Cable (1)" />
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/f3/99/a5/a23a3015890070b0d7073a0c7d.png" title="Product Equipment" alt="Product Equipment" />
</p>
<p>
<img src="http://i.bosscdn.com/product/51/cf/69/e165af845ee36542a0000ba26f.jpeg" title="132KV CABLE READO FOR LAYING OUT ON THE JOBSITE" alt="132KV CABLE READO FOR LAYING OUT ON THE JOBSITE" />
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/a8/60/ed/9c1b4983be76edf3252df92bbf.jpg" title="high voltage cable project 2" alt="high voltage cable project 2" />
</p>
<p>
<img src="http://i.bosscdn.com/product/92/40/8b/e165f33cab3921dab935727964.png" title="Test Equipment" alt="Test Equipment" />
</p>
<p>
<img src="http://i.bosscdn.com/product/2a/66/b1/bed15da7536a392be896f0fe96.jpg" title="high voltage cable pack4" alt="high voltage cable pack4" />
</p>
<p>
<img src="http://i.bosscdn.com/product/6e/b5/d6/8a497a7f967ff08169e346b11e.jpg" title="power cable durm" alt="power cable durm" />
</p>
<p>
<img src="http://i.bosscdn.com/product/48/ce/cb/1762ddd8159f25da99c7ebd5c9.png" title="Certificates" alt="Certificates" />
</p>
<p>
<img src="http://i.bosscdn.com/product/96/72/8e/5d6fbbf41b93bdcc4d3af3639c.png" title="Shipping Method" alt="Shipping Method" />
</p>bjhygkcable.com

  其他類似產品
 
300V Flame Resistant Fire Proofing Cable

300V Flame Resistant Fire Proofing Cable
230KV 3000mm2 XLPE Insulated electric wire high volt cable

230KV 3000mm2 XLPE Insulated electric wire high volt cable
1x1000 mm2 38/66(72.5)kV CU/XLPE/LS/CWS/HDPE POWER CABLE

1x1000 mm2 38/66(72.5)kV CU/XLPE/LS/CWS/HDPE POWER CABLE
1KV Copper Conductor Construction Application Low Volt cable

1KV Copper Conductor Construction Application Low Volt cable
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .