登入 加入會員 求助
 
Beijing Huayuan Gaoke Cable Co.,Ltd.
 
 
Recommended Results 
 
High Volt 66KV Aluminum Conductor XLPE Insulated Power Cable 

  產品分類 : 電子電工->電子零件->撓性扁平電纜

     
High Volt 66KV Aluminum Conductor XLPE Insulated Power Cable
       

  產品規格
 
Model No:    YJLLW02
  Country  CN
  Brand  HUAYUAN YONGTONG
  Packing  DRUMS
  Minimum Order  1000
  Payment Term  L/C,T/T,D/P,Western Union

 

  產品描述
   
  <p>
<span style="font-family:'Times New Roman';font-size:16px;">High Voltage 66KV Aluminum Conductor XLPE Insulated Power Cable</span>
</p>
<p>
<span style="font-family:'Times New Roman';font-size:16px;">1. Application</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">This product is suitable for 66KV-220KV high voltage,extra-high-voltage transmission and distribution line.</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Mechanical properties and electrical performance accord with IEC60840 and IEC62067 standard,</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">And GB/T11017-2002,GB/Z18890-2002,GB/T22078-2008.</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">2. Cable structure</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Conductor/ Inner shield/ Insulation/ Outer shield/ Buffer layers/ Sheath/ Outer sheath</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">3.66kv-220kv XLPE insulated electric cable description of the process</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">1) Conductor</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Conductor is aluminum.&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Conductor cross section 800mm² and below layers of pressed manner using good conductor roundness, pressed factor.&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">1000 mm² conductor cross-section and is divided over the use of the conductor, effectively reducing the skin effect of the conductor set,</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">&nbsp;increase the carrying capacity of the cable. For my company's largest division conductor cross section 3000mm² .</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Conductor material can be twisted into the swelling to achieve watertight along the conductor.</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">2) Insulation</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Conductor shield, insulation, insulation shield while using VCV three towers stand out.</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Company Vertical high crosslinking shop 129m, shop built with three vertical crosslinked production lines,</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">three production lines were imported from Finland and Germany TROESTER Maillefer company.&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Three production lines are equipped with front and rear preheating system,&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">which can effectively remove moisture inside the conductor, insulation and more uniform heating.&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Production lines are equipped with German Skikora online cornering instrument to control the insulation eccentric to a minimum.</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Online stress relief system can effectively reduce the insulation core internal residual stress, and further improve the electrical and mechanical properties of the cable.&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;">Three production lines are all-dry crosslinking and cooling.&nbsp;</span><br />
<span style="font-family:'Times New Roman';font-size:16px;"></span>
</p>
<p style="font-family:Arial, Helvetica, sans-serif;background-color:#FFFFFF;">
<span style="color:#0066CC;font-family:'Times New Roman';font-size:16px;"><span style="line-height:normal;font-family:'Times New Roman';font-weight:bold;font-size:16px;">Main&nbsp;test&nbsp;voltage</span></span>
</p>
<div class="rich-text-table" style="color:#222222;font-family:Arial, sans-serif;background-color:#FFFFFF;">
<table style="width:437pt;border:1px solid #CCCCCC;">
<tbody>
<tr>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">item&nbsp;/voltage&nbsp;level</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">38/66</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">48/66</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">64/110</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">76/132</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">127/220</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">290/500</span>
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">Partial&nbsp;discharge&nbsp;test</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">57</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">72</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">96</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">114</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">191</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">435</span>
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">AC&nbsp;voltage&nbsp;test</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">95</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">120</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">160</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">190</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">318</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">580</span>
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">Outer&nbsp;sheath&nbsp;DC&nbsp;voltage&nbsp;test</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">25</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">25</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">25</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">25</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">25</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">25</span>
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">Impulse&nbsp;voltage&nbsp;test</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">320</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">450</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">550</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">650</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">1050</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">1550</span>
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">frequency&nbsp;voltage&nbsp;test&nbsp;after&nbsp;impulse&nbsp;voltage</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">95</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">120</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">160</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">190</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">318</span>
</p>
</td>
<td style="border:1px solid #CCCCCC;">
<p>
<span style="font-family:'Times New Roman';font-size:16px;">580</span>
</p>
</td>
</tr>
</tbody>
</table>
</div>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/a8/60/ed/9c1b4983be76edf3252df92bbf.jpg" title="high voltage cable project 2" alt="high voltage cable project 2" />
</p>
<p>
<img src="http://i.bosscdn.com/product/c4/ff/7b/4118f21820cb6339b9902bed38.jpg" title="66KV HV CABLE radiation4" alt="66KV HV CABLE radiation4" />
</p>
<p>
<img src="http://i.bosscdn.com/product/28/45/84/c38f8d1d1c7772e7f4bc59872b.jpg" title="66KV HV CABLE radiation 1" alt="66KV HV CABLE radiation 1" />
</p>
<p>
<img src="http://i.bosscdn.com/product/6e/b5/d6/8a497a7f967ff08169e346b11e.jpg" title="power cable durm" alt="power cable durm" />
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/96/72/8e/5d6fbbf41b93bdcc4d3af3639c.png" title="Shipping Method" alt="Shipping Method" />
</p>bjhygkcable.com

  其他類似產品
 
Bare Conductor ACSR Horse High Voltage Cable BS215 ISO 9001

Bare Conductor ACSR Horse High Voltage Cable BS215 ISO 9001
0.6/1kv 4x120mm2 XLPE Insulated PVC Outer Sheath Power Cable

0.6/1kv 4x120mm2 XLPE Insulated PVC Outer Sheath Power Cable
1KV Copper Conductor XLPE Insulation PVC Outer Sheath

1KV Copper Conductor XLPE Insulation PVC Outer Sheath
1C*300 mm2 33kV XLPE Insulated Power Cables

1C*300 mm2 33kV XLPE Insulated Power Cables
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .