登入 加入會員 求助
 
Wenzhou Korlen Electric Appliances Co., Ltd.
 
 
Recommended Results 
 
Hot Sale MCB High-breaking 240V-415V Switch 

  產品分類 : 電子電工->電子零件->配線器材

     
Hot Sale MCB High-breaking 240V-415V Switch
       

  產品規格
 
Model No:    KNB6-63
  Country  CN
  Brand  Korlen
  Packing  carton
  Minimum Order  1000
  Payment Term  L/C,T/T

 

  產品描述
   
  <p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
&nbsp; &nbsp; &nbsp; KNB6-63&nbsp;High-breaking&nbsp;Miniature Circuit Breaker is&nbsp;mainly used in the line of AC 50/60Hz, rated working voltage to&nbsp;415V,&nbsp;and rated current to 63A as protection against overload and short-circuit. It can be used as infrequent on-and-off operation and changeover.
</p>
<p class="MsoNormal">
&nbsp; &nbsp; &nbsp;It complies with standard of GB10963 and IEC/EN60898.
</p>
<table class="mce-item-table" style="color:#000000;font-family:arial;font-size:12px;width:483px;height:299px;" cellspacing="1" cellpadding="0">
<tbody>
<tr class="firstRow">
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Frame class
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
63A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Rated working voltage
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
240V/415V
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Rated frequency
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
50/60Hz
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Rated working current
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
6.10.16.20.25.32.40.50.63A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Making and breaking capacity
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
10000A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Release type
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
C
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Poles
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
1.2.3.4P
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Mechanical life
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
10000
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
Electric life
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
4000
</p>
</td>
</tr>
</tbody>
</table>
The over-current tripping unit protection feature&nbsp;
<p>
<br />
</p>
<p class="MsoNormal">
<table class="mce-item-table" cellspacing="1" cellpadding="0">
<tbody>
<tr class="firstRow">
<td style="border:1px solid #DDDDDD;">
<p>
Sequence<br />
NO .
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Release
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Test<br />
current I/In
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Start state
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Tripping<br />
time
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Expected<br />
restlt
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #DDDDDD;">
<p>
1
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
c
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
1.13In
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Cold state
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
t≤1h
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Not tripping
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #DDDDDD;">
<p>
2
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
c
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
1.45In
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Start right after<br />
the serial NO .<br />
1 test
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
t<1h
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Tripping
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #DDDDDD;">
<p>
3
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
c
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
2.55In
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Cold state
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
1s<t<60s
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Tripping
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #DDDDDD;">
<p>
4
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
c
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
5In
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Cold state
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
t≤0.1s
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Not tripping
</p>
</td>
</tr>
<tr>
<td style="border:1px solid #DDDDDD;">
<p>
5
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
c
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
10In
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Cold state
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
t<0.1s
</p>
</td>
<td style="border:1px solid #DDDDDD;">
<p>
Tripping
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p>
<img src="http://i.bosscdn.com/product/34/3e/fb/74aa92ff456cc20c601c75b76c.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="worker" alt="worker" /><img src="http://i.bosscdn.com/product/60/43/76/8b2fadf9ddfb8b671a63b64ab3.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="workers " alt="workers " /><img src="http://i.bosscdn.com/product/37/87/b8/029b596fd0df391cf3d2d7a8df.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="workers in workshop" alt="workers in workshop" />
</p>
<p>
<b>&nbsp; &nbsp;</b>Product Series: Miniature Circuit Breaker (MCB) is denoted by [KNB". Residual Current Circuit&nbsp;Breaker (RCCB) is denoted by [KNL". AC Contactor is denoted by [KNC". Molded Case Circuit Breaker (MCCB) is denoted by KNM". Manual Motor Starter (MMS) is denoted by [KNS". Residual Circuit Breaker with Over-current Protection (RCBO) is denoted by [KNLE" and finally, Thermal Relay is also denoted by [KNR"
</p>
<p>
<br />
</p>
<p>
<br />
</p>korlenelectric.com

  其他類似產品
 
Manual Motor Starter with Thermo Magnetic Protection

Manual Motor Starter with Thermo Magnetic Protection
Miniature Circuit Breakers 6KA The Best Switch

Miniature Circuit Breakers 6KA The Best Switch
High Quality Terminal Distribution Electrics 240V RCCB

High Quality Terminal Distribution Electrics 240V RCCB
Low Voltage Miniature Circuit Breaker 415V Normal Type

Low Voltage Miniature Circuit Breaker 415V Normal Type
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .