登入 加入會員 求助
 
Filtemc Electronic Equipment Co.,Ltd
 
 
Recommended Results 
 
AC 3 phases 4 lines series filters 

  產品分類 : 能源及原料->其他->電磁波遮蔽

     
AC 3 phases 4 lines series filters
 
 
       

  產品規格
 
Model No:    AC 3 phases 4 lines series filters
CountryCN
Brandfiltemc
Materials
size
Weight1.6
ColorWhite
PackingCarton box
Minimum Order500
Payment TermT/T

 

  產品描述
   
  AC 3 phases 4 lines series filters
1.Features&Applications:
Low leakage current,good performance of common mode and differential mode interference suppression.
Widely used in machine tool device,inverter power supply,inverter equipment,industry equipment and medical appliance,etc.
Rated current:1A-400A.
2. Technical data:
Rated voltage:250/440VAC
Test voltage:2250VDC(line to line) and 2700VDC(line to ground).
Climatic category:25/085/21.
Operating frenquency:50/60Hz.
Insulation resistance:>200MΩat500VDC.
3.Tabulates
FT310-6:6A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.38Kg(Weight).
FT310-10:10A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.51Kg(Weight).
FT310-20:20A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.60Kg(Weight).
FT310-50:50A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.1(Electrical schematics),M6Stud(Termination),1.0Kg(Weight).
FT310-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M8Stud(Termination),3.2Kg(Weight).
FT310-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M10Stud(Termination),3.0Kg(Weight).
FT320-10:10A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).

FT320-20:20A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT320-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.4(Dimension),
Fig.2(Electrical schematics),M6Stud(Termination),1.6Kg(Weight).
FT320-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.2(Electrical schematics),M8Stud(Termination),6.0Kg(Weight).
FT320-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.2(Electrical schematics),M10Stud(Termination),7.0Kg(Weight).
FT320-200:200A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.2(Electrical schematics),M10Stud(Termination),11.5Kg(Weight).
FT3200-6:6A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.65Kg(Weight).
FT3200-10:10A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.65Kg(Weight).
FT3200-20:20A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT3200-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.3(Electrical schematics),M6Stud(Termination),3.2Kg(Weight).
If you want to get information about Dimension and outline drawing,Electrical schematics,Insertion loss(dB),please contact with(Xu Kuishan)Filtemc Electronic Equipment Co.,Ltd


AC 3 phases 4 lines series filters
1.Features&Applications:
Low leakage current,good performance of common mode and differential mode interference suppression.
Widely used in machine tool device,inverter power supply,inverter equipment,industry equipment and medical appliance,etc.
Rated current:1A-400A.
2. Technical data:
Rated voltage:250/440VAC
Test voltage:2250VDC(line to line),1760VDC(line to neutral) and 2700VDC(line to ground).
Climatic category:25/085/21.
Operating frenquency:50/60Hz.
Insulation resistance:>200MΩat500VDC.
3.Tabulates
FT410-6:6A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.4Kg(Weight).
FT410-10:10A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.4Kg(Weight).
FT410-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M8Stud(Termination),3.1Kg(Weight).
FT410-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M10Stud(Termination),3.1Kg(Weight).
FT420-10:10A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT420-20:20A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M6Stud(Termination),1.0Kg(Weight).
FT420-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.2(Electrical schematics),M6Stud(Termination),3.0Kg(Weight).
FT420-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.2(Electrical schematics),M8Stud(Termination),4.0Kg(Weight).
FT4200-6:6A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.6Kg(Weight).
FT4200-10:10A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.6Kg(Weight).
FT4200-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.3(Electrical schematics),M6Stud(Termination),3.0Kg(Weight).
FT4200-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.3(Electrical schematics),M10Stud(Termination),5.6Kg(Weight).
FT430-10:10A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.4(Dimension),
Fig.4(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT430-20:20A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.4(Dimension),
Fig.4(Electrical schematics),M6Stud(Termination),1.5Kg(Weight).

FT430-50:50A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.4(Electrical schematics),M6Stud(Termination),3.1Kg(Weight).
FT430-100:100A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.4(Electrical schematics),M8Stud(Termination),6.9Kg(Weight).
If you want to get information about Dimension and outline drawing,Electrical schematics,Insertion loss(dB),please contact with(Xu Kuishan)Filtemc Electronic Equipment Co.,Ltd


   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .