登入 加入會員 求助
 
Suqian Sunshine Electric Power Automation Equipment Co., LTD
 
 
Recommended Results 
 
Three Phase Portable Watthour Meter Calibration System 

  產品分類 : 電子電工->電類產品->其他->瓦時計

     
Three Phase Portable Watthour Meter Calibration System
       

  產品規格
 
Model No:    SJJ-1X
  Country  CN
  Brand  Suyuan

 

  產品描述
   
  Application
SJJ-1X is applied to the calibration of various electronic and inductive three phase watthour meter, three phase multifunctional electronic meter, three phase multi-rate watthour meter, three phase pre-paid watthour meter, including positive and negative phase active, reactive four-quadrant verification. With 3-wire and 4-wire real reactive reference standard, it is capable of calibration for various artificial reactive or real reactive watthour meter. The system is also fit for the calibration of power frequency voltmeter, ammeter, frequency meter, phase meter, single phase and three phase power meter, etc.
Function and feature
1. At present, SJJ-1X is the most powerful, most compact, lightest, portable, automatic multifunctional watthour meter calibration system with biggest current output domestically and the most desirable reference standard and lab test equipment.
2. With internal high-accuracy, wide-range and multifunctional standard reference, JJY-301 is capable of testing various watthour meter and electrical measuring instrument easily.
3. Large LCD display is used as the interface with high definition and Chinese language displayed. Using keyboard the operation is more convenient and simple.
4. High current output 0~100A , convenient for calibration of high current watthour meter.
5. Single phase power supply is convenient for users with various occasions.
6. It has multiple protection system with high speed, that makes the device more reliable. Also it has sound and light warning unit.
7. quipped with special keyboard, the device can indicate automatically the united unit and separated unit phase characteristics of all kinds of meters during user's manual verification, by which it is more convenient.
8. As required by the protocol, automatic test can be carried out on watthour meter's startup, creeping, fundamental error, standard deviation, 8-hour and 24-hour variation.
9. With the help of special intelligence software and rotary encoder, users can change arbitrarily each phase voltage, current,phase, frequency at any time and calibrate easily various digital or pointer type voltage, current, phase, frequency, etc. meters.
10. Having dedicated calibration software, JJY-301 can be connected easily to system computer to calibrate watthour meter and other AC digital/pointer type meter. Testing data can be processed and stored and exchanged by network. Diagram and table printing function is also possessed.
11. It can test watthour meters with different constant, and calibrate the constant.
12. The parameters, such as voltage, current, power(apparent, active, reactive), phase, power factor, frequency, etc. can be real-time measured. The real time vector diagram and harmonics analysis can be displayed also.
13. All types of bar code input is acceptable.
14. With RS485 port, it is very convenient to connect with all kinds of foreign and domestic watthour meters.
15. Automatic detection of communication protocol function is available
16. The communication protocol complies with all stipulations of DL/T645-1997 and IEC1107, and it can be modified as user's requirement.
17. Clock reference and GPS clock can be connected.

Other functions
With EMCS2002 meter calibration software, we can carry out tests for three phase electronic multifunctional watthour meters . The following tests can be combined at random or be performed separately, conveniently and swiftly.
Daily timing error test
Time interval switching error test
Indicated value of demand error test (maximum demand)
Multifunction meter running test (meter running combined error test)
Various communication test
Meter address read and setting
Time interval and zone setting
GPS broadcast timing
Register indicated value calibration (Register combined error test)
Demand circular error test
Constant calibration
Reading meter display data arbitrarily
Meter serial number reading and inspection
Various password and code verification and setting

  其他類似產品
 
Three phase 10-slot multi-functional watthour meter calibration system

Three phase 10-slot multi-functional watthour meter calibration system
Single-phase Watthour Meter Field Calibrator

Single-phase Watthour Meter Field Calibrator
Three-phase Watt-hour Meter Field Calibrator

Three-phase Watt-hour Meter Field Calibrator
 
   


[ Back Products Catalog ]

Commerce 會員:
請登入您的 帳號 跟 密碼, 系統將自動為您填入您的相關基本資料!
 
帳號:
密碼:
記住我的帳號
 
 
填寫下列表格並寄送詢問函.所有的詢問信函將會自動寄發給你想聯絡的公司
主旨
內容 ﹙ 請勿輸入公司名稱、Email、電話、傳真、網址 ﹚
   

 


公司簡介:

*公司名稱
*E-mail
*國家
*聯絡人
網址
*電話
- -
傳真
- -
*郵遞區號
*城市
*街道地址
*企業形態
批發商   出口商 進口商 製造商
大盤商 零售商  代理商 Retrofitter 使用者
其他, 請詳細說明:
*安全密碼
請輸入所顯示的安全密碼


網站導覽 l 隱私權政策 l 服務團隊 l 合作提案 l 聯絡我們 l 幫幫我 l 廣告刊登 l  B2B商業夥伴
    .